The most reliable steam boiler, steam generator manufacture

Electric Heating Steam Boilers

electric-heating-steam-boilers

Electric heating steam boilers is a new way of heating, pollution-free, green environmental protection

Advantage of electric heating steam boiler


 No combustion cabinet and no necessity of a chimney: Thus it is not necessary to take the heat loss into consideration and the heat efficiency almost amounts to 98%. This kind of electric-heated steam boiler can meet the strictest standards for emission and fire prevention. Stepwise time-dividing input method is adopted to control the electric heating elements, thus facilitating users to flexibly adjust the heat productivity of the boiler. It will not take long for the boiler to start or stop. The adjustment range of the operational load is wide and the operation is simple. High-quality electrical elements assure the service life of products. High-quality products made in China or foreign countries are selected for the accessories. The testing and inspection for the boiler shall be carried out so as to guarantee the normal operation of the boiler for a long time.

Automatic pollution discharge: the control system carries out the real-time inspection for the ion concentration in the water; when the concentration exceeds the set value, the electromagnetic valve for pollution discharge is automatically opened so as to realize the automatic pollution discharge; then the water pump starts and fresh water is injected so as to prevent the heat-absorbing surface from incrustation.
Incrustation alarming: special technology is adopted to monitor and control the situation of the incrustation of the heat-absorbing surface in real time; in case of any excessive incrustation, the alarm will automatically perform.
The stepwise time-dividing input method is adopted to control the electrical elements so as to extend the service life of the heating elements and simultaneously and to minimize the hit of the boiler on the grid system, thus ensuring more reliable operation of the boiler.

Parameter Table of Electric Heating Steam Boilers


 

Item Rated Power Power Rated Pressure Rated Steam Temperature Efficiency Water Volume Steam Outlet Weight Tranportation Dimension
LDR0.06-0.4 0.06 45 0.4 151 99 0.27 DN25 230 900*750*1545
LDR0.1-0.4 0.1 75 0.4 151 0.32 DN25 340 900*750*1610
LDR0.2-0.4 0.2 150 0.4 151 0.44 DN25 440 900*750*1970
LDR0.3-0.7 0.3 240 0.7 170 0.75 DN32 610 1212*1262*2030
LDR0.5-0.7 0.5 360 0.7 170 1.28 DN40 745 1312*1460*2230
WDR0.5-0.7 0.5 360 0.7 170 1.02 DN40 755 2406*1278*1695
WDR0.7-0.7 0.7 540 0.7 170 1.28 DN40 905 2456*1360*1795
WDR1-0.7 1 720 0.7 170 1.58 DN50 1060 2586*1480*1855
WDR2-1.25 2 1440 1,25 194 1.85 DN80 1280 2780*1680*2060